Description
The Doppler Fetal Monitor YR02180 combines cutting-edge technology with user-friendly features, making it an essential tool in both operating theaters and intensive care units. With a state-of-the-art 17-inch LCD screen and semi-modular parameter capabilities, this monitor offers flexibility and precision. The standard configuration includes ECG, SpO2, TEMP, NIBP, RESP, and PR/HR, providing comprehensive monitoring in clinical environments. Its optional features, such as a touch screen and various advanced monitoring parameters, enhance its usability for specialized applications.
Market Price
The market price for a Doppler fetal monitor ranges widely based on features and capabilities. The Doppler Fetal Monitor YR02180 generally falls within the range of $3,500 to $4,200. This price spectrum allows buyers to choose the specific configuration that best meets their clinical needs while ensuring affordability.
Frequently Asked Questions
What types of patients can use this fetal monitor?
The YR02180 is designed for use with adult, pediatric, and neonatal patients.
Is training required to operate the monitor?
While no extensive training is required, a basic understanding of patient monitors and physiological parameters is recommended.
Does the monitor come with a warranty?
Yes, the monitor is covered by a standard manufacturer’s warranty. For detailed information, please refer to the warranty documentation provided with the product.
Advantages and Disadvantages
The YR02180 offers several advantages, including comprehensive patient monitoring, ease of use, and optional advanced features like touchscreen and bispectral index monitoring. However, the initial setup and calibration can require time if all optional features are installed, and certain advanced features may incur additional costs.
Field Use
In clinical practice, the Doppler Fetal Monitor YR02180 provides reliable monitoring of vital signs, which is crucial for patient safety during surgeries and in critical care. Its compact design and modular options make it suitable for diverse healthcare settings, adapting efficiently to different patient needs.
Recommendations
To maximize the performance of the YR02180 monitor, it’s recommended to regularly calibrate the device and update its software as needed. Ensuring regular maintenance checks will prolong the life of the device and maintain its accuracy.
Features
The Doppler Fetal Monitor YR02180 features a vibrant 17-inch LCD display, modular parameter capabilities, and a flexible setup. It comes standard with ECG, SpO2, TEMP, NIBP, RESP, and PR/HR functions, with the option to expand with touch screen and other advanced monitoring parameters.
Technical Specifications
Model | YR02180 | |
ECG
|
Lead mode | 5 Leads(RA,LA,LL,RL,V) |
Connection method | I, II, III,AVR,AVL,AVF,V | |
Lead Mode | 3 Leads (RA,LA,LL) | |
Connection method | I, II,III | |
Gain | x250, x500, x1000, x2000 | |
Accuracy | ±5% | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -1.0~+1.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate
|
Measuring range | 40~240bpm |
Accuracy | ±3bpm | |
Resolution | 1bpm | |
Sensitivity | >200UVp-p | |
Respiration
|
Method | Impedance between R-F(RA-LL) |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 7~120BrPM | |
Neo/Ped | 7~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
NIBP
|
Method | Oscillometric |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm / 40~150bpm | |
Alarm Type | SYS, DIA, MEAN | |
Resolution | ||
Pressure | 1mmHg | |
SPO2
|
Display | Number of SPO2,waveform of capacity,Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~99% (±2%) | |
Pulse rate range | 0~300bpm | |
TEMP
|
Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Actualization interval | about 1 Second. | |
Average Time Constant | <10 Second. |