Automated Slide Staining YR436-1: Technical Performance and Safety
The YR436-1 automated slide staining system represents a significant advancement in laboratory staining technology. Engineered with a flexible, low-noise transmission system and durable materials, this device ensures stable operation and reliable performance. In this article, we will delve into the product description, market price, frequently asked questions, pros and cons, field usage, and recommendations for the YR436-1 automated slide staining device.
Product Description
The YR436-1 is a compact device that can easily fit near the sectioning area for optimal workflow. Its intuitive touchscreen interface facilitates easy operation, making it user-friendly for both experienced and new laboratory personnel. The integrated touchscreen boasts a highly intelligent control system that provides a comprehensive range of functions, reliable performance, and straightforward operation.
Constructed with a robust APS-coated casing, the YR436-1 is easy to clean and highly resistant to corrosion. It can stain 24 slides simultaneously in a rapid staining process. After the staining process is complete, the slide rack can either stop or be submerged in a cup, as per user selection, with an alert sound to notify the user.
This device is ideal for Hematoxylin and Eosin (H & E) staining, as it features a flexible, low-noise, and wear-resistant transmission system utilizing high-quality imported materials. An intelligent automatic input/output/drain flow system ensures adequate washing performance at every step while enhancing water efficiency. Additionally, the YR436-1 can store and program up to 25 sets of staining protocols, with each protocol containing 30 editable steps for customized staining processes.
| Feature | Specification |
|---|---|
| Model | YR436-1 (current) |
| Number of Tanks | 15 (Station 1 for drying, Station 2 for washing, 13 for reagents) |
| Capacity of Each Tank | Approximately 350ml |
| Treatment Duration in Tank | Adjustable between 0 and 59 minutes, 0 and 59 seconds |
| Temperature Control Accuracy | ± 1% |
| Drip Time | Adjustable between 0 and 60 seconds |
| Stirring Frequency | Adjustable between 0 and 6 times/minute |
| Operating Voltage | AC220V ± 10% 50Hz (standard model); AC 110V ± 10% 60Hz |
| Power | 400W |
| Dimensions | 925 × 250 × 260 mm (L × W × H) |
| Weight | 27 kg |
Market Price
The market price for the YR436-1 automated slide staining system is approximately $2800 USD or €5513 EUR. This pricing reflects the advanced technology and reliable performance of the machine, making it a worthwhile investment for laboratories seeking efficiency and precision in their staining processes.
Frequently Asked Questions
What is the capacity of the tanks in the YR436-1?
The YR436-1 features 15 tanks, with each tank having a capacity of approximately 350ml.
Can the staining protocols be customized?
Yes, the YR436-1 can store and program up to 25 sets of staining protocols, with each protocol consisting of 30 editable steps.
How can the device improve workflow efficiency in a laboratory?
With its compact design, rapid staining process, and intelligent flow systems, the YR436-1 optimizes workflow by allowing simultaneous staining of multiple slides and ensuring precise washing performance.
Is the device easy to operate for new users?
Yes, the intuitive touchscreen interface makes it easy to learn and operate for both new and experienced users, facilitating a smooth user experience.
What type of staining is the YR436-1 ideal for?
The YR436-1 is particularly suitable for Hematoxylin and Eosin (H & E) staining, among other histological staining procedures.
What safety features does the YR436-1 include?
The YR436-1 includes an error alert operation to notify users of any issues during the staining process, ensuring safety and reliability.
Where can I request a quote for the YR436-1?
You can request a quote for the YR436-1 automated slide staining device through our dedicated inquiry channels.
Pros and Cons
Pros
- Compact design for optimal placement and workflow.
- Intuitive touchscreen interface for easy operation.
- Simultaneous staining capability for up to 24 slides.
- Customizable protocols to suit various staining needs.
- Durable materials ensure long-term reliability and performance.
Cons
- The initial investment cost may be high for some laboratories.
- Requires regular maintenance to ensure optimal performance.
Field Usage
The YR436-1 automated slide staining device is primarily used in clinical laboratories, research institutions, and educational settings where histological analysis is conducted. Its ability to efficiently stain multiple slides simultaneously makes it an invaluable tool in pathology and anatomical studies. The advanced control system enhances reproducibility and accuracy, which are critical in diagnostic applications.
Recommendations
For laboratories looking to enhance their staining processes, investing in the YR436-1 automated slide staining system is highly recommended. Ensure that laboratory personnel are trained adequately to operate the device effectively. Regular maintenance checks are essential to uphold the machine's performance and lifespan. Consider integrating this device alongside other laboratory equipment to streamline workflows further.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture every device to the highest standards of excellence. Our intuitive and seamless online purchasing channels are designed for your convenience, securing the most competitive prices. Hesitate no longer — we bring science to life, it is time to become part of our community.